Code | Description |
0000D8 | External Library Error. |
10020 | Firmware DIMM Test failure. |
10021 | Memory DRAM DIMM Test failure. |
10023 | EEROM Test failure. |
01002D | The Main PCA cannot communicate with the Carriage. |
10040 | Error in Paper-axis Encoder quadrature. |
10041 | Error in Scan-axis Encoder quadrature. |
10042 | Error in Service Station-axis Encoder quadrature. |
10050 | PostScript Processing Error. |
01009X | Error in Paper-axis Motor Encoder |
02xxxx | PostScript/Firmware Error. |
048xxx | The EIO card is from a third party vendor and may not be fully compliant with the IIO Protocol specification 2.0 OR the EIO Card firmware is not updated. |
04Cxxx | EIO Accessories (EIO Card/Hard Disk Drive) Error. |
60301 | One of the Printheads has an Internal Electrical Problem. |
60305 | Thermal Shutdown error (one of the Printheads has gone above the maximum Temperature). 00000000 - Cyan Printhead Failed. 00000001 - Magenta Printhead Failed. 00000002 - Yellow Printhead Failed. 00000003 - Black Printhead Failed. |
60309 | Problem with setting the Voltage of the Printheads. |
06030A | Error in finding the Mark Encoder. |
06030B | The Ambient Temperature measured is out of the normal range. |
70100 | Firmware Error. |
80001 | PostScript Error. |
09xxxx | EIO Accessories (EIO Card/Hard Disk Drive) Error. |
0A0000 | The Air Pressure is below the minimum requirement. |
0A0010 | Problem in Pressurizing the Air System. |
0A0020 | Error in Calibrating the APS Sensor. |
0A0030 | Problem in Depressurizing Air System. |
0A0040 | Ink Tubes Initialization Failure Due to Low Air Pressure. |
0A0050 | The Printer has detected a leak in the Tubes System before the life of the System. |
0A0060 | The Printer has detected a leak in the Tubes System after the life of the System. |
0A0070 | The Backup EEROM contents stored in the Tubes System are not consistent with the ones required by the firmware. |
0B0000 | Bad Ambient Temperature measured. |
0B0001 | Bad Humidity read. |
0B0002 | Bad IDS pressure read. |
0B0003 | ADC0 Internal channels check Failure. |
0B0004 | Unable to detect Pump. |
0B0005 | Unable to detect Valve. |
0B0006 | The Trailing Cable has been incorrectly connected OR the fuse in the Electronics Module has been burned. |
0B0007 | Unable to detect Vacuum Fan. |
0B0008 | Unable to detect Cooling Fan. |
0B0009 | Unable to detect Aerosol Fan (Included on the Right Cover). |
0B000A | Primer Shutdown Error. |
0B000B | Pump or Pressure Sensor not working. |
0B000C | Serial Device ADC test failure |
0B000D | 24 V source test failure. |
0C0030 | Bad Drop Detector. |
0C0032 | Drop Detector not Calibrated for all Printheads. |
0C1000 | Primer not Calibrated. |
0C1001 | Primer Shutdown Error. |