Code | Description |
1 | Internal RAM The read/write of the RAM on the Main PCA was diagnosed and an error was detected. |
2 | SRAM The read/write of the SRAM on the Main PCA was diagnosed and an error was detected. |
4 | Flash ROM The program area in the Flash ROM is sum-checked, and it could not be read, causing an error. |
8 | PIO The read/write of a specific Parallel I/O (PIO) was tested and an error was detected. |
10 | NVRAM Problems with the NVRAM detected. |
20 | FPGA (Main PCA) The read/write of the FPGA-ATG (Band Memory) and FPGA-RSM (Mask Memory) registers on the Main PCA was diagnosed and an error was detected. |
40 | FPGA (Carriage PCA) The read/write of the FPGA-PTC (Print Timing Controller) and FPGA-PDD (Print Data Distributor) registers on the Carriage PCA was diagnosed and an error was detected. |
80 | ASIC CONF (Main PCA) The program load from the Flash ROM on the Main PCA to the FPGA on the Main PCA or sum-check was not performed correctly and an error occurred. |
100 | ASIC CONF (Carriage PCA) The program load from the Flash ROM on the Main PCA to the ASIC on the Carriage PCA or sum-check was not performed correctly and an error occurred. |
200 | DRAM The read/write of the image band memory on the Main PCA was diagnosed and an error was detected |
400 | USB Register The read/write of the USB controller on the Main PCA was diagnosed and an error was detected. |
1110 | GA_ATG Block Clear Error The ATG band memory block erase does not end. This error is checked during Boot-Up sequence and printing. |
1111 | GA_ATG DMA Transfer Error There is a problem in the data path. This error is checked during printing. |
112x | Vacuum Fan Error x = 0: The Vacuum Fan (Wiping Side) has failed. x = 1: The Vacuum Fan (Center of the Platen) has failed. x = 2: The Vacuum Fan (Capping Side) has failed. |
1140 | Flash ROM Write Error A time-out error occurs when the NVRAM contents are being saved in the flash memory in Maintenance Mode and erasing does not end. |
1150 | Home Position Sensor Error The Carriage cannot be moved to it’s home position. |
1160 | Wiping Error When the Wiping Motor has been running for a while, the sensor fails to detect that the Motor has made one turn. |
1170 | Temperature Sensor Error The Temperature Sensor detects abnormal temperatures (-10C or lower or 85C or higher). |
1180 | Capping Motor Error Capping Motor over current is detected. |
119x | Head Relay Variable Supply Error Output voltages of the Head Relay Board are abnormal. |
11Ax | NVRAM Error The data in the NVRAM is incorrect. |
11C0 | Cap Position Error The Carriage position sensors have detected more than a 2mm gap during the capping operation. |
11D0 | Cooling Fan Error When the Printhead temperature reaches above 43C, the Printer will check whether the temperature drops below 43C during printing. This error will appear if the temperature does not drop below 43C after 10 minutes. |
1,10E+01 | Long Term Storage Error This error is displayed when the Printer has been left switched OFF for more than 31 days. |
120x | Printhead Drive IC Error The Piezo Drive IC on a Printhead is too hot (85C or higher) or too low (- 10C or lower). |
121x | Printhead Temperature Error The Printhead temperature is too high (85C or higher) or too low (-10C or lower). x = 0: Printhead Number 1 (Black). x = 1: Printhead Number 2 (Light Magenta). x = 2: Printhead Number 3 (Light Cyan). x = 3: Printhead Number 4 (Yellow). x = 4: Printhead Number 5 (Magenta). x = 5: Printhead Number 6 (Cyan). |
1220 | Edge Sensor Error The Printer has problems detecting the edge of the Media. |
123x | Sub-Tank Sensor Error (Full or Half) The Full and Half Sensors on the Sub-Tanks are defective. x = 0: Printhead Number 1 (Black). x = 1: Printhead Number 2 (Light Magenta). x = 2: Printhead Number 3 (Light Cyan). x = 3: Printhead Number 4 (Yellow). x = 4: Printhead Number 5 (Magenta). x = 5: Printhead Number 6 (Cyan). |
124x | Ink Supply Sensor Error The Ink Supply Sensor does not change even though the specified time has passed after driving the Ink Supply Motor for the Sub-Tank. x = 0: Printhead Number 1 (Black). x = 1: Printhead Number 2 (Light Magenta). x = 2: Printhead Number 3 (Light Cyan). x = 3: Printhead Number 4 (Yellow). x = 4: Printhead Number 5 (Magenta). x = 5: Printhead Number 6 (Cyan). |
125x | Sub-Tank Supply Error The Sub-Tank Sensor does not switch to less than half even though ink has been consumed. x = 0: Printhead Number 1 (Black). x = 1: Printhead Number 2 (Light Magenta). x = 2: Printhead Number 3 (Light Cyan). x = 3: Printhead Number 4 (Yellow). x = 4: Printhead Number 5 (Magenta). x = 5: Printhead Number 6 (Cyan). |
126x | Trailing Cable Connection Error The Trailing Cable connected to the one of the following connectors is faulty. x = 0: Connector 9. x = 1: Connector 10. x = 2: Connector 11. x = 3: Connector 12. |
1700 | Servo Motor Error The Paper-Axis or the Scan-Axis Motor moves the Carriage, but the input from the Linear Encoder Sensor does not change. |
F_es: 0001 | Operation Code Exception |
F_es: 0002 | Slot Illegal Exception |
F_es: 0003 | Address Exception |
F_es: 0004 | DMA Error |
F_es: 0005 | NMI Occurrence (WatchDog Error) |
H01 | System Error Abnormal operation of the Heater Relay Assembly. |
H02 | Relay Board Error The Heater Board and the Relay Board are not connected together. |
H03 | Front Heater Temperature Error Temperature read by the Front Heater is abnormal (lower than -10C or higher than 70C). |
H04 | Rear Heater Temperature Error Temperature read by the Rear Heater is abnormal (lower than -10C or higher than 70C). |
H05 | Center Heater Temperature Error Temperature read by the Center Heater is abnormal (lower than -10C or higher than 70C). |
H06 | Front Heater Time-out Error The temperature of the Front Heater does not reach the preset temperature even after 15 minutes. |
H07 | Rear Heater Time-out Error The temperature of the Rear Heater does not reach the preset temperature even after 15 minutes. |
H08 | Center Heater Time-out Error The temperature of the Center Heater does not reach the preset temperature even after 15 minutes. |
H09 | Operation Panel Switch Error The specified switch is not pressed for 30 seconds or more when the diagnostics that verifies the switch action is executed. |
H10 | Zero Cross Error This error occurs when the diagnostics for the AC Relay is executed. |